FLOODED DEEP CYCLE BATTERY

2 YS 27P

Series 5000 Warranty 10 Years
Volts 2 BCI SPEC
Cells 1 Plates/Cell 27
Terminal Type Flag
Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer
Size & Thread 5/16"-18 x 1-1/2"
Cables 19" 4/0 interconnect cables *RE incl.
Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)
Float Voltage Range 2.25 V/cell @ 25°C (77°F)
Self-Discharge Rate 5%-10% per month at 25°C (77°F)
Capacity
Cold Crank Amps (CCA) 0°F / -17°C 4975
Marine Crank Amps (MCA) 32°F / 0°C 6219
Reserve Capacity (RC @ 25A) 5054 Minutes
Reserve Capacity (RC @ 75A) 1685 Minutes
Hour Rate Capacity / AMP Hour Current / AMPs
@ 100 Hour Rate 2969 AH 29.69 A
@ 75 Hour Rate 2185 AH 30.34 A
@ 50 Hour Rate 2020 AH 40.41 A
@ 20 Hour Rate 2106 AH 105.3 A
@ 15 Hour Rate 1959 AH 130.57 A
@ 10 Hour Rate 1748 AH 174.8 A
@ 8 Hour Rate 1643 AH 205.34 A
@ 5 Hour Rate 1411 AH 282.2 A
@ 1 Hour Rate 716 AH 716.04 A

Amphere hour capacity ratings based on specific gravity of 1.280.
Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.

Specifications
Weight 111.5 kg 246 lbs
Length 35.6 cm 14"
Width 22.9 cm 9"
Height Inc. Term. 80.3 cm 31.63"
Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process, battery components & electrolyte levels.
Electrolyte Reserve 95 mm 3.75"
Container (Inner) Polypropylene
Cover (Inner) Polypropylene - heat sealed to inner container
Container (Outer) High Density Polyethylene
Cover (Outer) High Density Polyethylene snap fit to outer container
Handles Molded

Cycle Life vs. Depth of Discharge

Voltage vs. Depth of Discharge

Rev.#3 | May 2018