FLOODED DEEP CYCLE BATTERY

6 FS 300

Series FS Warranty 1 Year
Volts 6 BCI 902
Cells 3 Plates/Cell 17
Terminal Type DT
Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer
Size & Thread 5/16"-18 x 1-1/2"
Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)
Float Voltage Range 2.25 V/cell @ 25°C (77°F)
Self-Discharge Rate 5%-10% per month at 25°C (77°F)
Capacity
Cold Crank Amps (CCA) 0°F / -17°C 844
Marine Crank Amps (MCA) 32°F / 0°C 1055
Reserve Capacity (RC @ 25A) 642 Minutes
Reserve Capacity (RC @ 75A) 175 Minutes
Hour Rate Capacity / AMP Hour Current / AMPs
@ 100 Hour Rate 384 AH 3.84 A
@ 75 Hour Rate 378 AH 5.25 A
@ 50 Hour Rate 357 AH 7.14 A
@ 20 Hour Rate 300 AH 15 A
@ 15 Hour Rate 285 AH 19 A
@ 10 Hour Rate 264 AH 26.4 A
@ 8 Hour Rate 258 AH 32.25 A
@ 5 Hour Rate 237 AH 47.4 A
@ 1 Hour Rate 120 AH 120 A

Amphere hour capacity ratings based on specific gravity of 1.280.
Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.

Specifications
Weight 44 kg 97 lbs
Length 31.1 cm 12.25"
Width 18.1 cm 7.13"
Height Inc. Term. 36.2 cm 14.25"
Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process, battery components & electrolyte levels.
Electrolyte Reserve 44 mm 1.75"
Container Polypropylene
Cover Polypropylene
Handles Rope / Plastic Handle

Cycle Life vs. Depth of Discharge

Voltage vs. Depth of Discharge

Rev.#3 | May 2018